Velocity Edge GX325 Manual de usuario Pagina 33

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 32
33
Installing Continuously Glued Gaskets
1. Make sure the gasket groove area is clean and dry prior to
regasketing.
2. Apply a uniform layer of adhesive in the appropriate
gasket grooves. (A plastic bottle makes an ideal applicator,
provided the tip of the applicator is designed to provide a
bead that is approximately 1/8 in. wide.) Do not apply
adhesive in amounts that will allow it to ooze out when the
gasket is pressed into the groove. Apply adhesive at room
temperature (70°F). After the glue is applied to the plate,
it should be allowed to set for a minimum of 30 sec before
the gasket is set in place. Work on pairs of plates to allow
for this curing time.
The recommended adhesive for all elastomeric gaskets is
Pliobond 30. Pliobond 20 and 3M 1347 can also be used,
if Pliobond 30 is not available. Hardening adhesives are not
to be used. The number of gaskets that can be glued from
one pint bottle of Pliobond 30 glue may be approximated
as in Table 10.
3. Position the gasket on the plate making sure that the
recess in the gasket at the bleed passage location is up. Also,
when the proper side is up, the gasket code number will be
visible in the bleed passage area. Proper groove fit and flow
diverter access is dependent on end-to-end positioning. (See
Figures 15 and 32.)
4. Using finger pressure, firmly press the gasket into the same
grooves from which the original gasket was removed.
5. Compress the gasket by placing the plate under a weighted
MODEL NUMBER OF GASKETS/PINT
XP-005 122
UXP-010 100
UXP-100 85
UXP-200 60
GFP-030 50
UXP-060, SXP-070 35
UXP-400 30
UXP-110 30
SXP-400, SXP-140 30
GFP-080 25
UXP-801, UXP-802 10
GXD-006 50
GXD-012, GL-013, GC-016 50
GXD-018, GCP-010 35
GXD-026, GCP-026 30
GXD-042 20
GXD-051, GCP-051 17
Table 10
Glue Requirements
MODEL NUMBER OF GASKETS/PINT
GXD-037 30
GXD-064 18
GXD-091 15
GXD-118 13
GXD-060, GCP-060 20
GXD-100 18
GXD-140 14
GXD-180 15
GXD-085 16
GXD-145 14
GXD-205 12
GXD-265 10
GXD-325 8
GFP-057 19
GFP-097 18
GFP-187 15
GL-230, GL-330, GL-430 8, 7, 6
sheet of wood. The longer the compression time, the better
the bond. Twelve hours cure time at room temperature (70°F)
should be allowed to assure minimum required adhesion
of the gasket to the plate for all elastomers except EPDM.
EPDM gaskets require a minimum of 24 hr cure time at
room temperature (70°F) to assure an adequate bond. (When
several plates are being gasketed, they can be stacked on top
of each other with the weighted wood sheet placed on the
top plate of the stack.)
6. After compression time (step 5), use solvent to remove any
excess adhesive that may have seeped out past the edges of
the gasket.
7. Reinstall plate(s) in the unit insuring that the gasket surface
and the sealing surface of the plate ahead are wiped clean to
provide a positive seal.
8. Note that the “D” plate (always the plate next to the fixed
frame end) requires different gaskets. The purpose of the
“D” plate is to prevent fluid from flowing across the fixed
end frame. The only sealing surface on the “D” plate is the
port hole gaskets. D” plate gaskets for the UX series consist
of two half gaskets. “D” plate gaskets for the GFP-030 and
GFP-080 plates consist of four port hole gaskets and straight
strips, which fit in the gasket groove around the periphery of
the plate. The wide port gasket fits the widest groove, and
the narrow port hole gasket fits the narrow groove.
NOTE: Refer to page 24 when using mixed gaskets.