Technical InformationTI365O/98/en/01.10185414 01/10 03Ultrasonic Level SensorLUC-M**Compact transmitters for non-contactlevel measurement of fluids, p
Ultrasonic Level Sensor LUC-M**Performance characteristicsDOCT-0805F 01/2010 18541410Performance characteristicsReaction time The reaction time depend
Ultrasonic Level Sensor LUC-M**Installation conditionsDOCT-0805F 01/2010 18541411Installation conditionsInstallation variantsLUC-M10, LUC-M20For insta
Ultrasonic Level Sensor LUC-M**Installation conditionsDOCT-0805F 01/2010 18541412Installation conditions for level measurements• Do not install the se
Ultrasonic Level Sensor LUC-M**Installation conditionsDOCT-0805F 01/2010 18541413Installation conditions for flow measurements• Install the LUC-M** at
Ultrasonic Level Sensor LUC-M**Installation conditionsDOCT-0805F 01/2010 18541414Blocking distance,nozzle installationInstall the LUC-M** at a height
Ultrasonic Level Sensor LUC-M**Ambient conditionsDOCT-0805F 01/2010 18541415Ambient conditionsAmbient temperature -40 °C ... +80 °C (233 K ... 353 K)T
Ultrasonic Level Sensor LUC-M**Mechanical constructionDOCT-0805F 01/2010 18541416Mechanical constructionDesign, dimensions LUC-M10, LUC-M20Dimensions
Ultrasonic Level Sensor LUC-M**Mechanical constructionDOCT-0805F 01/2010 18541417LUC-M40 with mounting bracketDimensions in mm (inch)LUC-M30Dimensions
Ultrasonic Level Sensor LUC-M**Mechanical constructionDOCT-0805F 01/2010 18541418Flanges for LUC-M40Dimensions in mm (inch)WeightSuitable for A B C D
Ultrasonic Level Sensor LUC-M**Mechanical constructionDOCT-0805F 01/2010 18541419Housing design Types of housings• F12 housing with sealed terminal co
Ultrasonic Level Sensor LUC-M**Table of contentsDOCT-0805F 01/2010 1854142Function and system design. . . . . . . . . . . . . 3Measuring principle . .
Ultrasonic Level Sensor LUC-M**Human interfaceDOCT-0805F 01/2010 18541420Human interfaceDisplay and operating elementsThe LCD module LUC-Z15 for displ
Ultrasonic Level Sensor LUC-M**Human interfaceDOCT-0805F 01/2010 18541421On-site operation Operation with LUC-Z15The LC-Display LUC-Z15 allows configu
Ultrasonic Level Sensor LUC-M**Certificates and approvalsDOCT-0805F 01/2010 18541422Remote control Operation with PACTwareTM (for communication varian
Ultrasonic Level Sensor LUC-M**Ordering informationDOCT-0805F 01/2010 18541423Ordering informationProduct structureLUC-M10Product structureLUC-M20LUC–
Ultrasonic Level Sensor LUC-M**Ordering informationDOCT-0805F 01/2010 18541424Product structure LUC-M30Product structureLUC-M40LUC–M30– – –Certificate
Ultrasonic Level Sensor LUC-M**AccessoriesDOCT-0805F 01/2010 18541425Scope of delivery • instrument according to the version ordered• operating manual
Ultrasonic Level Sensor LUC-M**AccessoriesDOCT-0805F 01/2010 18541426Cantilever• The 50 mm (2 in) or 62 mm (2.4 in) orifices serve for the mounting of
Ultrasonic Level Sensor LUC-M**AccessoriesDOCT-0805F 01/2010 18541427Wall bracketAdapter flange forLUC-M10/LUC-M20Version with metrical threadVersion
Ultrasonic Level Sensor LUC-M**AccessoriesDOCT-0805F 01/2010 18541428Universal slip-on flange for LUC-M30Remote displayTechnical dataProzess connectio
Ultrasonic Level Sensor LUC-M**AccessoriesDOCT-0805F 01/2010 18541429Display and operating module LUC-Z15LC display for on-site operation of LUC-M** (
Ultrasonic Level Sensor LUC-M**Function and system designDOCT-0805F 01/2010 1854143Function and system designMeasuring principleE: empty distance; F:
Ultrasonic Level Sensor LUC-M**Supplementary documentationDOCT-0805F 01/2010 18541430Supplementary documentationOperating manual Depending on the comm
Ultrasonic Level Sensor LUC-M**Supplementary documentationDOCT-0805F 01/2010 18541431Safety Instructions The following safety instructions are supplie
Ultrasonic Level Sensor LUC-M**Supplementary documentationDOCT-0805F 01/2010 18541432Control drawings/installation drawingsThe following control or in
With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Servi
Subject to modificationsCopyright PEPPERL+FUCHS • Printed in Germanywww.pepperl-fuchs.comWorldwide HeadquartersPepperl+Fuchs GmbH68307 Mannheim · Ge
Ultrasonic Level Sensor LUC-M**Function and system designDOCT-0805F 01/2010 1854144Equipment architecture 4 mA … 20 mA output with HART protocolThe co
Ultrasonic Level Sensor LUC-M**InputDOCT-0805F 01/2010 1854145InputMeasured variable The distance D between the sensor membrane and the product surfac
Ultrasonic Level Sensor LUC-M**OutputDOCT-0805F 01/2010 1854146Example (for LUC-M30)For typical solid applications, a certain amount of dust coverage
Ultrasonic Level Sensor LUC-M**Auxiliary energyDOCT-0805F 01/2010 1854147Auxiliary energyTerminal compartment In the F12 housing, the terminals are lo
Ultrasonic Level Sensor LUC-M**Auxiliary energyDOCT-0805F 01/2010 1854148The digital communication signal is transmitted to the bus via a 2-wire conne
Ultrasonic Level Sensor LUC-M**Auxiliary energyDOCT-0805F 01/2010 1854149Cable entry • cable gland: M20 x 1.5 (recommended cable diameter 6 mm ... 10
Comentarios a estos manuales