29
Tightening the Plate Pack
The plate pack tightening length (distance between the facing
surfaces of the “S” and “E” frames) is given on the assembly
drawing and on the unit data plate. The tightening dimension
is identifi ed as “A Max.” and “A Min.” The unit is normally
tightened at the factory to the average dimension between “A
Max.” and “A Min.” “A Min.” is a minimum length. Consult the
SUPERCHANGER Engineering Department before tightening
the unit to a smaller dimension. CAUTION: On units
operating in excess of 200 psig, the tightening dimension is
to equal or approach the minimum dimension. The wrench
size required for the various SUPERCHANGER tightening bolt
diameters is shown below. Refer to the SUPERCHANGER
drawing for the actual bolt diameter.
Due to manufacturing tolerances, a unit is sometimes shipped
with a plate pack dimension greater than the minimum
dimension stated on the drawing. If leakage occurs, after a
period of time, tighten the unit to the minimum length. If the
plate pack length is shorter than the minimum length, damage
to the plates at contact points may result. If leakage occurs at the
minimum length, contact the SUPERCHANGER Engineering
Department for recommendations regarding gasket replacement
or additional tightening.
The end frame is
immovable with this
piping arrangement
Figure 39
Correct piping installation—disconnecting A and B connections will permit
movement of the end frame (top view).
Figure 40
Incorrect piping installation—the end frame is immovable (side view).
BOLT DIAMETER (in.) WRENCH SIZE (Across Flats) (in.)
3/4 1 1/4
1 1 5/8
1 1/4 2
1 1/2 2 3/8
1 3/4 2 3/4
2 3 1/8
2 1/4 3 1/2
2 1/2 3 7/8
An EZCHANGER Hydraulic Closing Device is available for assembly/disassembly of larger units. See page 45 for details.