Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting
3-9000-743 Rev U August 2014
Collecting logs and viewing Excel reports 285
9. When all of the data is collected, the SOS Calculator dialog appears (if a Computed SOS
value was entered, it will be included or if Manually entered SOS has been selected).
Click the
Calculate button and the SOS data is included in the Maintenance log
spreadsheet.
Figure 7-18 Speed of Sound dialog
10. Click the
Finish button for the Speed of Sound calculations.
11. Daniel CUI displays a message that the log data collection is complete and allows to you
open the file now or open it at a late time.
Figure 7-19 Log complete dialog
12. Click the
Yes button to view the Microsoft® Excel file or click the NO button to view the
reports at a later time. Daniel MeterLink returns you to the Maintenance and Reports
dialog box.
13. If you clicked the
Yes button in the previous step, Microsoft® Excel opens the log
reports.