232 Daily log
Section 6: Meter operation Reference, Installation, and Operations Manual
August 2014 3-9000-743 Rev U
The data points included in the daily log and the corresponding log action are as shown in the
table below. Data points required by the API Chapter 21 standard are marked with an asterisk
(*). (Refer to Section 6.6 for information on the log action types.) For information on a particular
data point, consult Daniel MeterLink online help. (There is a help topic for each data point. From
Daniel MeterLink, click on Help, click on Mark III Registers Reference, select the Index tab,
start typing the data point name until the desired point is highlighted, and then click the
Display button.)
Table 6-18 Daily log content
Data Point Log action
PosVolFlow*
Totalize and Snapshot
NegVolFlow*
Totalize and Snapshot
PosVolBase*
Totalize and Snapshot
NegVolBase*
Totalize and Snapshot
PosEnergy
Totalize and Snapshot
NegEnergy
Totalize and Snapshot
PosMass
Totalize and Snapshot
NegMass
Totalize and Snapshot
FlowTemperature*
Flow-Gated
FlowPressure*
Flow-Gated
AbsFlowPressure*
Flow-Gated
AccumFlowTime*
Totalize
AvgSndVel*
Flow-Gated
RhoMixFlow*
Flow-Gated
ZFlow*
Flow-Gated
ZBase*
Flow-Gated