Velocity Edge DualX Manual de servicio Pagina 301

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 400
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 300
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting
3-9000-743 Rev U August 2014
Maintenance log files and trend files 275
Maintenance logs or trend files are not created
When using Excel® XP or later, some of the worksheets in the Maintenance Logs or Trend files
are not created.
If the Inspection sheet of the Maintenance Log file or the Charts sheet of a Trend files is not
generated, it is probably because Excel® is not configured to allow Daniel MeterLink to run the
Visual Basic® script that generates the page. Excel® can be configured to allow Daniel
MeterLink to run the Visual Basic® script by following the instructions below.
To enable Excel® to work with Daniel MeterLink, open Microsoft® Excel,
1. Select the
Tools|Macr|>Security menu.
Figure 7-10 Excel® Tools Menu
2. The Security dialog appears. Select the
Trusted Sources (or if you are using Microsoft®
XP,
Trusted Publishers)tab.
Windows 2000 Excel® Menu Windows XP Excel® Menu
Vista de pagina 300
1 2 ... 296 297 298 299 300 301 302 303 304 305 306 ... 399 400

Comentarios a estos manuales

Sin comentarios