Reference, Installation, and Operations Manual Section 5: Startup and meter configuration
3-9000-743 Rev U August 2014
Temperature and Pressure page 151
2. If Fixed was selected for Temperature for meter corrections on the Startup Page, enter an
average temperature of the process fluid:
Table 5-17 Fixed Temperature Inputs
Daniel MeterLink
Display Name
Options and Guidelines
Fixed temperature
Enter the flow-condition temperature (°C or °F) within the range
[-130 °C, 200 °C]
Temperature alarm, Low limit
Enter a value (°C or °F) within the range [-130 °C, 200 °C]. An alarm is
generated when the temperature is at or below this limit value.
Temperature alarm, High limit
Enter a value (°C or °F) within the range [-130 °C, 200 °C]. An alarm is
generated when the temperature is at or above this limit value.
Alarm Selection
The Alarm selection determines what value to use while a live input is
in alarm. This value is common with the pressure Alarm selection so
when one is changed, the other will change to match.
Choose Last good value or Fixed value