Operation
6.4 Command sources
Drive converter cabinet units
Operating Instructions, 10/2008, A5E00288214A
199
6.4.2 "TM31 terminals" default setting
Prerequisites
The "TM31 Terminals" default setting was chosen during commissioning:
STARTER:
"TM31 Terminals"
AOP30:
"6: TM31 terminals
Command sources
U0DVWHUFRQWURODFWLYH
5(027(70
/2&$/2SHUDWRUSDQHO67$57(5
%XWWRQ/2&$/5(027($23
$VVXPHPDVWHUFRQWURO67$57(5
,QWHUQDOFRQWURO
2SHUDWRUSDQHO$23
&RQWUROSDQHO67$57(5
352),%86352),1(7
,QSXWWHUPLQDOV$70
Figure 6-11 Command sources - AOP30 ←→ terminal TM31
Priority
The priority of the command sources is shown in the diagram "Command sources - AOP30
←→ terminal TM31".
Note
The emergency OFF and motor protection signals are always active (regardless of the
command source).
For LOCAL master control, all of the supplementary setpoints are de-activated.