ALEOS 4.2.3 User Guide
148 20080616
Advanced
Assert DSR Assert DSR always when the device is in a data mode (UDP, TCP, etc.), or when the device
is in network coverage. Options are:
Always
In Data Mode
In Coverage
Default: Always
Assert DCD Assert DCD always, or when the device is in a data mode (UDP, TCP, etc.) or when the
device is in network coverage. Options are:
Always
In Data Mode
In Coverage
Default: Always
Enable CTS Assert CTS when there is network coverage. Options:
Disable
Enable
Default: Disable
DTR Mode Use DTR from the serial device, or ignore DTR (same as S211). Options:
Use DTR
Ignore DTR
Default: Ignore DTR
Quiet Mode Disable or enable display of device responses. Options:
Disable
Enable
Default: Disable
AT Verbose Mode Configure AT command responses. Options:
Verbose
Numeric
Default: Verbose
Call Progress Result
Mode
When enabled adds 19200 to CONNECT messages. Options:
Disable
Enable
Default: Disable.
Convert 12 digit
Number to IP Address
Converts 12 digit number to an IP address 111222333444 -> 111.222.333.444. Options:
Use as Name
Use as IP
Default: Use as Name.
Table 11-1: Serial Port Configuration
Field Description
Vista de pagina 147
1 2 ... 143 144 145 146 147 148 149 150 151 152 153 ... 248 249

Comentarios a estos manuales

Sin comentarios

Intermec Protectores De Pantalla manuales de usuario

Empezando en 0-9

Haga clic en el alfabeto a continuación para desplazarse a la lista completa de modelos que comienzan con esa letra

Modelos Tipo de documento
346-069-104
Ficha de datos   Intermec Touchpanel Protector, 3 paginas